Welcome to Trouble Free Pool We would like to welcome you to TFP, the webs leading Pool related website. We invite you to please Register to create a new account. Doing this will give you full access to the forums, where you will be able to receive personalized advice concerning your pool. We hope to see you soon!

Results 1 to 20 of 22

Page 1 of 2 1 2

Last

Thread: Jandy error code 145 Thread Tools

Display

02-17-2013, 03:29 PM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#1

Jandy error code 145 I have a Jandy Aqua Pure system and am getting a High Salt General fault on the handheld. The salt is reading 4800 but two pool stores get 3300. I replaced the sensor (for the third time in 5 years) and the new one has the daughter board. The service light is on in the outside panel error code 145 displays (high salt) and any help from Jandy has lead me know where (they replaced the sensor no charge because of all of my problems since the pool was built, and the apparently new there is a problem with it). Is anyone else having the same issues? If I have to replace everything I don't want Jandy! Reply With Quote

02-18-2013, 01:01 AM

Pool Clown

#2

Re: Jandy error code 145

In the Industry

Originally Posted by pat in st. cloud

and the new one has the daughter board.

Did you push the little button on it to calibrate the salinity?

Join Date: Location: Posts:

Sep 2008 Silicon Valley, CA 1,638

Factory Warranty Station for: Jandy/Zodiac, Pentair, Sta-Rite, Raypak, Polaris, and Paramount pool cleaning systems. Reply With Quote

02-18-2013, 01:49 PM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#3

Re: Jandy error code 145 Yes, I pressed the button on the new daughter board and still get the same error code and the same salinity reading. I even tried (at Jandy's suggestion) hitting the reset button on the front panel. Still the same results. Reply With Quote

02-18-2013, 01:50 PM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#4

Re: Jandy error code 145 What is the chance that the daughter board or the new trisensor is bad?

Reply With Quote

02-19-2013, 11:04 AM

Pool Clown

Re: Jandy error code 145

In the Industry

Join Date: Location: Posts:

#5

What is the color of the epoxy that holds the three sensors in place (white or black)?

Sep 2008 Silicon Valley, CA 1,638

Factory Warranty Station for: Jandy/Zodiac, Pentair, Sta-Rite, Raypak, Polaris, and Paramount pool cleaning systems. Reply With Quote

02-19-2013, 11:37 AM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#6

Re: Jandy error code 145 Kind of a blackish dark grey color. Definitely not white.

Reply With Quote

02-19-2013, 11:46 AM

Pool Clown

Re: Jandy error code 145

In the Industry

Join Date: Location: Posts:

#7

And you held the button down till the light came on?

Sep 2008 Silicon Valley, CA 1,638

Factory Warranty Station for: Jandy/Zodiac, Pentair, Sta-Rite, Raypak, Polaris, and Paramount pool cleaning systems. Reply With Quote

02-19-2013, 05:27 PM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#8

Re: Jandy error code 145 Just to be sure, I did it again. Pressed and held the button on the daughter board until the light went out and came back on again. Still getting 145 error and the Salt reading is 4.4 which is about where it's been. It used to go up and down as the water level went up or down but it doesn't seem to have an effect on it now. I also am noticing the Chloirne level is falling, which it has been stayling up without any adjustments. The Chlorine level is what prompted the discussion with Jandy (last fall) as the cell and the sensor were replaced under warrenty a couple of years ago (but there was no daughter board on what was put in, and I guess that's the reason they replaced the sensor?). Thanks! Reply With Quote

02-20-2013, 09:13 AM

ping

#9

Re: Jandy error code 145 I found these instructions on how to recalibrate the aquapure salt reading. I've never tried it, but you can see what this does for your unit.

Join Date: Location: Posts:

Jun 2011 Long Beach, CA 2,672

•Press the “Salinity”button and hold it until it beeps 3 times. The system will beep when you push it and then at 5 seconds and again at 10 seconds. Release the button after the 3rdbeep. •Press and release the “Temperature “button within 5 seconds to enter the salinity calibration screen. •The system will display the salinity reading, press the up arrowto increase the reading and the down arrow to decrease the reading. •When the proper reading is reached press the “Temperature”button within 5 seconds to store it in memory

16k gal plaster with raised spa, Jandy DEV60 filter, 2 HP 2-speed SHPF Jandy Stealth pump Hayward Aqua Rite T-15 SWCG, Jandy LXi 400k BTU NG heater, 350 sq.ft. of Sun Star solar panels, TF-100 Test Kit, Dolphin s300i Cleaner Test Kits . Pool Math . Chlorine/CYA Chart . The SLAM Process Reply With Quote

02-20-2013, 09:52 AM

Pool Clown

Re: Jandy error code 145

In the Industry

Join Date: Location: Posts:

#10

Unless the unit had been calibrated previously, in an attempt to correct a fault, i would not advise calibrating. Cold water is going to give you a false reading. Given the time of year, and i do realize you have had this problem since last fall, i would either wait until spring when the water warms up a bit, or another thing you can try is heat up the spa to any where past 60 and see if the unit will give an accurate salinity count then.

Sep 2008 Silicon Valley, CA 1,638

Factory Warranty Station for: Jandy/Zodiac, Pentair, Sta-Rite, Raypak, Polaris, and Paramount pool cleaning systems. Reply With Quote

02-20-2013, 10:27 AM

ping

#11

Re: Jandy error code 145 Originally Posted by Pool Clown

Join Date: Location: Posts:

Jun 2011 Long Beach, CA 2,672

Unless the unit had been calibrated previously, in an attempt to correct a fault, i would not advise calibrating. Cold water is going to give you a false reading. Given the time of year, and i do realize you have had this problem since last fall, i would either wait until spring when the water warms up a bit, or another thing you can try is heat up the spa to any where past 60 and see if the unit will give an accurate salinity count then.

Good point Pool Clown. I figured his water was warm enough for him to start using his generator. I looked up St. Cloud and it is in MN, not too warm there. I thought St. Cloud might have been in FL. Pat in St. Cloud, what is the water temp? If it is below 60 then like Pool Clown suggested, wait till the water warms up and then see if you have the same problems. Make sure the cell and sensor are clean.

16k gal plaster with raised spa, Jandy DEV60 filter, 2 HP 2-speed SHPF Jandy Stealth pump Hayward Aqua Rite T-15 SWCG, Jandy LXi 400k BTU NG heater, 350 sq.ft. of Sun Star solar panels, TF-100 Test Kit, Dolphin s300i Cleaner Test Kits . Pool Math . Chlorine/CYA Chart . The SLAM Process Reply With Quote

02-20-2013, 11:20 AM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#12

Re: Jandy error code 145 Yes we are in St Cloud Florida, and the water temp is around 67 at night up to 73 during the day (we've had a cold spell this last week was up to almost 80 a week ago. Reply With Quote

02-20-2013, 11:56 AM

ping

#13

Re: Jandy error code 145 Water temp isn't the problem then. Make sure the cell and sensor are clean, and if they are, I would try to recalibrate just to see if everything starts working correctly.

Join Date: Location: Posts:

Jun 2011 Long Beach, CA 2,672

By the way, my aquapure worked fine when the water got down to 56 degrees this winter. The salinity reading actually dropped closer to what my test strips measured. Now that my water is 75 degrees, the salinity reading on the aquapure is rising, and is 800 ppm more than my test strips. This batch of test strips consistantly measured 500 ppm or so lower than the last batch of strips. I never had a problem with the aquapure shutting down due to salinity, so I just leave it alone.

16k gal plaster with raised spa, Jandy DEV60 filter, 2 HP 2-speed SHPF Jandy Stealth pump Hayward Aqua Rite T-15 SWCG, Jandy LXi 400k BTU NG heater, 350 sq.ft. of Sun Star solar panels, TF-100 Test Kit, Dolphin s300i Cleaner Test Kits . Pool Math . Chlorine/CYA Chart . The SLAM Process Reply With Quote

02-20-2013, 12:03 PM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#14

Re: Jandy error code 145 just tried to recalibrate. I didn't get any beeps whenI pressed the salinity button on the board (the main board not the daughter board). I'll pull the cell and sensor later today and see if it needs cleaned. Just did it a month ago. I did notice two different temperature buttons on the board. Maybe it's not the same model??? Reply With Quote

02-20-2013, 12:50 PM

ping

#15

Re: Jandy error code 145 You should be able to push the buttons on the front panel. They are listed as A-Down Arrow, B-Up Arrow, C-Salinity, D-Temp. I don't think you need to be pushing any buttons on the main board, just on the panel. Like I said though, I haven't tried this.

Join Date: Location: Posts:

Jun 2011 Long Beach, CA 2,672

16k gal plaster with raised spa, Jandy DEV60 filter, 2 HP 2-speed SHPF Jandy Stealth pump Hayward Aqua Rite T-15 SWCG, Jandy LXi 400k BTU NG heater, 350 sq.ft. of Sun Star solar panels, TF-100 Test Kit, Dolphin s300i Cleaner Test Kits . Pool Math . Chlorine/CYA Chart . The SLAM Process Reply With Quote

02-20-2013, 04:38 PM

pat in st. cloud Join Date: Posts:

Feb 2013 26

#16

Re: Jandy error code 145 Ping - You are a genius! I went back out and did as you said (and I was able to set the Salinity level at 3.3 which is what the pool store got). The service light is out and the 145 error code is gone! Jandy needs to hire you! You are 100% better than their customer service! You have no idea how much I appreciate your help and advice! Reply With Quote

08-16-2014, 07:07 PM

zenlen Join Date: Location: Posts:

#17

Re: Jandy error code 145 Aug 2012 Sac, CA 20

Originally Posted by ping

I found these instructions on how to recalibrate the aquapure salt reading. I've never tried it, but you can see what this does for your unit. •Press the “Salinity”button and hold it until it beeps 3 times. The system will beep when you push it and then at 5 seconds and again at 10 seconds. Release the button after the 3rdbeep. •Press and release the “Temperature “button within 5 seconds to enter the salinity calibration screen. •The system will display the salinity reading, press the up arrowto increase the reading and the down arrow to decrease the reading. •When the proper reading is reached press the “Temperature”button within 5 seconds to store it in memory

thank you Ping. This cleared the general fault/high salt reading.

16.5K Pebbletec. Jandy 1.5 epump. Nature 2 Fusion Soft SWG. Polaris 280 w booster pump. Reply With Quote

10-04-2014, 03:40 PM

towney Join Date: Location: Posts:

#18

Re: Jandy error code 145 Apr 2007 Central Florida 84

When I try Ping's fix I get a H.H Salinity GPL showing on the panel. Unable to move it up or down. Mine is the 1400 AquaPure Apurem and only 4 months old. Any ideas on my code 145 High Salt 10400 reading? Could PH high or low cause this for before error pool was registering 2800 salinity and for what it's worth we have had a tremendous amount of rain over the past week here.

18k free form IG w/spa (4 jets), Paramount in floor cleaning system, Starite system 3 filter, Jandy 2hp ePump, Sta-Rite SR400LP Maxi-therm propane heater, Jandy aquapure/apurem 1400 SWCG, Jandy automation PS4 w/PDA, IntelliBrite 120v 5-G LED pool & spa lights, 2" piping and (3)4x12 (5)4x10 Fafco Sunsaver Solar Panels. Reply With Quote

03-28-2015, 01:30 PM

bcoughlin Join Date: Location: Posts:

#19

Re: Jandy error code 145 Mar 2015 Dallas 2

Those instructions worked perfectly. I was having the exact same problem where my Jandy was saying I had too much chlorine and giving me an error 145 code. I followed your below instructions and recalibrated the salt levels down to 3.5. The error code disappeared and the unit is producing chlorine again. Much thanks PING!! BC Dallas, Texas

I found these instructions on how to recalibrate the aquapure salt reading. I've never tried it, but you can see what this does for your unit. •Press the “Salinity”button and hold it until it beeps 3 times. The system will beep when you push it and then at 5 seconds and again at 10 seconds. Release the button after the 3rdbeep. •Press and release the “Temperature “button within 5 seconds to enter the salinity calibration screen. •The system will display the salinity reading, press the up arrowto increase the reading and the down arrow to decrease the reading. •When the proper reading is reached press the “Temperature”button within 5 seconds to store it in memory[/QUOTE] Reply With Quote

03-28-2015, 01:38 PM

bcoughlin Join Date: Location: Posts:

#20

Re: Jandy error code 145 Mar 2015 Dallas 2

I just followed the instructions posted by Ping and it worked perfectly. Thanks Ping! I had the same 145 error code saying I had too much chlorine when, in reality, I had very low chlorine. The re-calibration worked and my pool water temp was 62 degrees. I manually reduced the chlorine levels to 3.5 and the service light and error code disappeared and the unit is producing chlorine again. Reply With Quote

Page 1 of 2 1 2

Last

« Previous Thread | Next Thread »

Forum

Equipment - Build, Use, and Repair

Salt Water Chlorine Generators (SWG)

Jandy error code 145

Posting Permissions

You may not post new threads You may not post replies You may not post attachments You may not edit your posts

BB code is On Smilies are On [IMG] code is On [VIDEO] code is Off HTML code is Off Forum Rules

-- Default Style

Contact Us PoolMath on iOS PoolMath on Android Top TFP on Instagram

All times are GMT -5. The time now is 11:34 AM. Powered by vBulletin® Version 4.2.4 Copyright © 2017 vBulletin Solutions, Inc. All rights reserved. Spaminator provided by [OzzModz] Spaminator - vBulletin Mods & Addons Copyright © 2017 OzzModz Ltd.

Loading...

Jandy error code 145 - Trouble Free Pool

Forgot your password? User Name Password Log in Help Register Remember Me? Home FAQ Pool School Forum Actions Forum Forum ...

309KB Sizes 4 Downloads 22 Views

Recommend Documents

Jandy Heater Error Codes - WordPress.com
pool or spa heater. The heater generator units, such as the Jandy AquaPure®. Electronic and the installation codes refe

Nature 2 Fusion issues - Trouble Free Pool
May 15, 2015 - Nature 2 Fusion issues. SO I have a brand new pool - got a SWG to make my life "easier". It's been anythi

Pump Efficiency Data - Trouble Free Pool
Mar 1, 2009 - [EDIT2] The CEC recently removed the ability to directly download the Excel spreadsheet. You now have to d

Southern California New Pool Quote - Trouble Free Pool
Nov 3, 2013 - 18k IG pebblesheen pool, Hayward ProLogic P4 w/ T-15 SWG, Pentair 1HP 2-speed Superflo, Hayward 6020 DE fi

Intellipro flow rates - Trouble Free Pool
Apr 2, 2013 - I saw an old post with a link to a spreadsheet that enabled you to calculate gpm from rpm and watts for an

Raypak Pool Heater Error Code Water Sw Open - WordPress.com
The Raypak 156K BTU natural as pool heater is designed for easy installation Water connections are 2" and 17 3/4" on cen

Hydraulics 101 - Have you lost your head? - Trouble Free Pool
Jun 7, 2007 - Edit - Before reading this article, you may want to first familiarize yourself with this Pool School artic

Need help with GPM Estimate Spreadsheet - Trouble Free Pool
Mar 28, 2011 - I recently installed a Hayward EcoStar SP3400 VSP and I'm trying to get an accurate estimate of the gpm s

QuickBooks Error Code H303 | QuickBooks Error H303 | Toll-free +18772499444
Facing QuickBooks Error Code H303? Get QuickBooks customer service at our toll-free QuickBooks error support number +187

Xbox error code
To become the best web portal for single mothers all over the world. S. ViP. 211211k222222k Vip 211211k222222k Spanish S