PECO MCC Motor Control Center Equipment Specification Technical Data: Motor Control Center Single & Two Door Enclosure Construction: Steel Nema 4 Enclosure Length: 37.5” (.95 m) Single Door, 49” (1.24 m) Two Door Height: 66” (1.68 m) Single Door, 75” (1.91 m) Two Door Width: 11” (.28 m) Single Door, 13” (.33 m) Two Door Vehicle Height Clearance: n/a Water Input: n/a Water Output: n/a Electrical Requirements: 208vac/230vac/460vac/
[email protected] 60 Hertz Hydraulic Requirements: n/a Air Requirements: n/a Shipping Weight: 250+ lbs. (114+ kg) Depends on number of starters. Controller Function: n/a MCC208 = 10 starters max in Single Door Enclosure MCC230 = 12 starters max in Single Door Enclosure MCC460 = 18 starters max in Single Door Enclosure MCC575 = 18 starters max in Single Door Enclosure *If application requires more starters than listed, you must order a Two Door Panel. Short Circuit Current Rating is 10,000 amps (5,000 amps at 230VAC & 208 VAC) If a higher SCCR is required by local codes, PECO must be informed prior to ordering this panel. A (2) Door “Special” Panel will be used to accommodate the necessary components.
PECO Car Wash Systems – 244 Rex Boulevard – Auburn Hills – Michigan – 48326 – USA – 1-248-299-5800 09/25/09 S:\Engineering Doc's\WEB EQUIPMENT SPEC FILES\ELECTRICAL DEVICES\994020 MCC EQSPEC.doc Page 1 of 3
PECO MCC Motor Control Center
1 [0.95] 372
11 [0.28] TOP VIEW FRONT VIEW
SIDE VIEW
60 [1.52] 66 [1.68]
6 [0.15] ONE DOOR
1 [0.55] 212 8 [0.20]
8 [0.20]
PECO Car Wash Systems – 244 Rex Boulevard – Auburn Hills – Michigan – 48326 – USA – 1-248-299-5800 09/25/09 S:\Engineering Doc's\WEB EQUIPMENT SPEC FILES\ELECTRICAL DEVICES\994020 MCC EQSPEC.doc Page 2 of 3
PECO MCC Motor Control Center
49 [1.24]
13 [0.33] TOP VIEW
FRONT VIEW
SIDE VIEW
60 [1.52] 75 [1.91]
15 [0.38]
1 [0.84] 334 8 [0.20]
TWO DOOR
8 [0.20]
PECO Car Wash Systems – 244 Rex Boulevard – Auburn Hills – Michigan – 48326 – USA – 1-248-299-5800 09/25/09 S:\Engineering Doc's\WEB EQUIPMENT SPEC FILES\ELECTRICAL DEVICES\994020 MCC EQSPEC.doc Page 3 of 3